Walk-through Metal Detector - WTS9
For Use in: - Airports, Military Premises, Embassies, Shopping
Centres, Prisons, Airports Seaports and all Kinds of Business.
Tourist, Educational & Entertainment Environments.
Specifications
- International Norms
- Multi-Zone Right, Left, Top, Bottom and Middle
- Auto Calibration
- Red/Green, Stop and Go LEDs’
- LED illuminated warnings at control and side panels
- 10 Security levels with 246 adjustable options at each Graphic Display
- 10 Metal density levels on Vu-meter display (Green-Yellow-Red)
- Audi alarm at 10 levels
- Alarms Counter
- In & Outgoing Counters separately at 5 digits (Visible / Invisible)
- Lock for control panel and 4-digit pin code
- Automatic display of failure
- Uninterrupted Power Supply
- English Menu (Optional: Other Languages)
- Easy programming, monitoring with LCD display
- No necessity for maintenance
- Different colours available
- CUSTOM DESIGNS
SRC / SCADA Remote Control
RS 232 port & accessories (optional) observation, failure reading
etc. operations of the detectors are performed by cable (max.100 m.)
and /or by PTT line by modem.
The unit can be adjusted, data and failure modes observed by remote
Control, by cable to a local PC or via PTT line via modem.
Set Up Detail
From, (com1) to (com 4) - 4 different serial communication ports
can be used.
This is selected by the Com Port SELECT. If this is done
through telephone lines then the port with ‘modem’ must be selected.
Enter the phone number of the targeted detector to S9 Phone Number
and press Dial button. Then SRC will connect Modem by the dialled phone
number. All operations, either by phone or locally by cable in principal
are the same, for connection and communication.
All of the Walk-Thru Detector unit a network should be separately
numbered ie 1 - 16. (All units are numbered 1 from the factory and
renumbered by the user!)
The Detector is selected by its GATE Number for control and so the
relative information on screen is renewed. STATUS displays the situation.
STOP sign shows that the operation has been performed successfully.
Due to communication line or any failure, READ ERROR sign will be seen.
All failures are displayed in this manner.
On Level Setting from 1 to 10, 10 different channels can be selected
separately. At each of them (from 0 to 245 digits) 246 sensitivity
levels can be adjusted. The active channel and its alarm level can be
observed at the text box.
Alarm Volume Level displays audio volume and can be adjusted to 10
different levels. 0 will shut off the volume.
Counters displays incoming In Counter and outgoing Out Counter,
Alarm Counter information.
In Settings active language and Counters values are displayed or
changed to Counter Invisible.
The Above-mentioned parameters are displayed once for the selected
detector.
After necessary modifications new values are changed at the
appropriate fields and than entered by Save button. Then the detector
resets and uses the new adjusted values.
The Refresh button updates every 30 seconds and during the activation
of this process Save operation can not be carried out.
After the Control Program is completed, all of the connections are
closed and telephone line is shutdown.
The Factory Settings returns the Unit to default values from factory.
To view this product as a PDF please click here.
For more information - please click here to contact us.
|